DJS-0.1-C Conductivity electrode for pure water, BNC

 29,360

Brand Details

  • Designed for purified water and ultra-pure water conductivity measurement (0 to 200µS/cm, K=0. 1)
  • Equipped with a glass flow cell, eliminating the impact from CO2
  • High sensitivity platinum chip sensor ensures high accuracy in low conductivity
  • Compatible with any conductivity meters that adopt BNC connector
Delivery
Home Delivery - Rs 150
Sold By
FLYUP Technology - Goods & Sales Departments
Positive Seller Ratings

98%

Ship on Time

100%

Chat Response Rate

97%

Direct Contact

Description

DJS-0.1-C Conductivity electrode for pure water, BNC

Apera DJS-0.1-C Conductivity Electrode (K=0.1)   is designed for purified water and ultra-pure water conductivity measurements. It’s equipped with a glass flow cell, which eliminates impact from CO2 in the air. The high-sensitivity platinum chip sensor design ensures high accuracy in low range conductivity solutions (0 to 200µS/cm). 3Ft cable length. BNC connector.. To achieve temperature compensation, users need to use a separate temperature probe or manually input temperature values. 3Ft cable length.

  • Designed for purified water and ultra-pure water conductivity measurement (0 to 200µS/cm, K=0. 1)
  • Equipped with a glass flow cell, eliminating the impact from CO2
  • High sensitivity platinum chip sensor ensures high accuracy in low conductivity
  • Compatible with any conductivity meters that adopt BNC connector

WARRANTY of DJS-0.1-C Conductivity

We warrant this electrode to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of SIX MONTHS from the delivery.

This limited warranty does NOT cover any issues due to:

  • Accidental damage
  • Improper use
  • Normal wear and tear
  • Transportation
  • Storage
  • Failure to follow the product instructions
  • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
  • Unauthorized repair

 

0/5 (0 Reviews)

Reviews

There are no reviews yet.

Be the first to review “DJS-0.1-C Conductivity electrode for pure water, BNC”

Your email address will not be published. Required fields are marked *

Related Product You May Need To Know

Apera DO803 Luminescent Optical DO Probe

DO803 Luminescent Optical DO Probe

Apera Instruments MP500 Temperature Probe/Electrode

MP500 Temperature Probe, RCA Connector

Apera LabSen 243-6 Glass-body pH/Temp. Electrode for Test Tubes (>0.2mL)

LabSen 243-6 Glass-body pH/Temp. Electrode for Test Tubes

Apera LabSen 251 Glass-body pH Electrode for Semi-Solid Samples

LabSen 251 Glass-body Spear pH Electrode

Apera LabSen 331 POM-body pH/Temp. Electrode for Wastewater, Emulsions, and Suspensions

LabSen 331 POM-body pH Electrode for Wastewater, Emulsions

Apera LabSen 331 POM-body pH/Temp. Electrode for Wastewater, Emulsions, and Suspensions

LabSen 333 POM-body pH/Temp. Electrode for Wastewater

Apera LabSen 371 POM-body Flat pH Electrode for Surface Test

LabSen 371 POM-body Flat pH Electrode for Surface Test

Apera LabSen 863 pH/Temp. Electrode

LabSen 863 pH/Temp. Electrode for High-temp

Apera LabSen 823 Glass-body pH/Temp. Electrode

LabSen 823 Glass-body pH/Temp. Electrode Milk, Yogurt, Cream

Apera LabSen 761 Titanium-body Blade Spear pH Electrode for Meats

LabSen 761 Titanium-body Blade Spear pH Electrode for Meats

Apply Now

DJS-0.1-C Conductivity electrode for pure water, BNC

These boards are typically used for displaying information such as menus, advertisements, and schedules in a large, easily visible format. They are designed to be used for indoor or outdoor applications and are typically highly customizable. They can also be used for interactive applications such as touchscreens and interactive kiosks.

A LED digital board is a type of video wall consisting of individual LED screens that are arranged in a variety of shapes and sizes. The boards are often used for displaying advertising, sports scores, weather forecasts, and other realtime information. They are also used in digital signage applications, providing a visual, interactive way to communicate with customers. The boards feature longlasting LED technology and are available in a variety of sizes, resolutions, and shapes.

LED digital boards typically use a USB data card to control the board and manage content. The card can be programmed to display text, images, videos, and other multimedia content, and can be updated remotely over the internet. The data card is typically connected to the board via a RJ45 network cable.

The power supply of a LED digital board will depend on the type of board and the type of LEDs used. Generally, it can be powered by a DC voltage source ranging from 12V to 24V or an AC voltage source ranging from 110V to 220V.

Flyup Technology Hosting

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.